Appendix C: Using an IRIS IR Capture Unit
199
VisualArchitect v1.1
CONFIDENTIAL AND PROPRIETARY. COPYRIGHT, AMX LLC, 2006
3.
The two digits that appear in the display represent the current baud rate setting.
4.
Press the up or down pushbuttons to reset the baud rate.
5.
Press and hold the up, down, and send pushbuttons again to set the new baud rate. The Ready LED
lights to indicate the IRIS unit is ready to capture a RC function.
IRIS - Baud Rate And Display Digits
IRIS - Cables And Adapters
Depending on your IRLIB programming configuration, one or more cables may be required. Connectors
are shown from the wiring side.
Computer-to-NetLinx Control System (DB-25 to DB-9):
Computer-to-NetLinx Control System (DB-9 to DB-9):
Baud Rate And Display Digits
Baud Rate Display Digits
• 300
03
• 600
06
• 1200
12
• 2400
24
• 4800
48
• 9600
96
FIG. 127
Computer-to-NetLinx Control System (DB-25 to DB-9) wiring diagram
FIG. 128
Computer-to-NetLinx Control System (DB-9 to DB-9) wiring diagram