Appendix B: Wireless Technology
186
MVP-5200i Modero Viewpoint Widescreen Touch Panel
Configuring Modero Firmware via the USB Port
The MVP-5200i needs to be configured to connect with a PC to transfer firmware via the mini-USB port.
To configure the touch panel:
Step 1: Configure the panel for a USB Connection Type
1.
After completing the installation of the USB driver (for more information, refer to the
Upgrading
the Modero Firmware via the USB port
section on page 99), confirm the proper installation of the
large Type-A USB connector to the PC's USB port, and restart your computer.
2.
After the panel powers up, hold the reset button to display the
Setup
Page (for more information,
refer to the
Accessing the Setup and Protected Setup Pages
section on page 23) and open the
Protected Setup
page.
3.
Press
System Settings
to open the
System Settings
page.
4.
Toggle the blue
Type
field in the
Master Connection
section until the choice cycles to
USB
.
5.
Press the
Back
button on the touch panel to return to the
Protected Setup
page.
6.
Press the
Reboot
button both to save any changes and to
restart the panel.
Remember that the
panel’s connection type must be set to
USB
prior to rebooting the panel and prior to inserting the
USB connector.
7.
ONLY AFTER
the unit displays the first panel page should you
THEN
insert the mini-USB
connector into the Mini-USB Port on the panel. It may take a minute for the panel to detect the new
connection and send a signal to the PC,
indicated by a green System Connection icon
.
If a few minutes have gone by and the
System Connection
icon still does not turn green,
complete the procedures in the following section to set up the Virtual Master and refresh the
System from the Online Tree. This action sends out a request to the panel to respond and
completes the communication, turning the
System Connection
icon green.
8.
Repeat steps 2 and 3 to return to the
System Settings
page
Step 2: Prepare Studio for communication via the USB port
1.
From the
Start
menu in Windows XP, open the
Network Connections
dialog (
Start
>
Settings
>
Network Connections
>
Local Area Connection
).
2.
Look for the Local Area Connection reading
Local Area Connection, AMX USB Device Link
and
double-click on it to open the Local Status.
3.
Press the
Properties
tab to open the
Local Area Connection Properties
section.
4.
Press the
Properties
button to open the
TCP/IP Properties
dialog box.
5.
Set the IP address to an address within the same subnet as the panel IP address specified within the
USB IP settings of the panel. For instance, if the default IP address on the device is
12.0.0.2
, set the
IP address to
12.0.0.1
.
6.
Set the Subnet Mask to
255.255.255.0
.
7.
In the
TCP/IP Properties
dialog box, click
OK
.
8.
In the
Local Area Connection Properties
, section, click
Close
.
ALL
fields are then greyed out and read-only. However, they still display any previous
network information.
Summary of Contents for Modero Viewpoint MVP-5200i
Page 28: ...Accessories 20 MVP 5200i Modero Viewpoint Widescreen Touch Panel ...
Page 56: ...Configuring Communication 48 MVP 5200i Modero Viewpoint Widescreen Touch Panel ...
Page 68: ...Setup Pages 60 MVP 5200i Modero Viewpoint Widescreen Touch Panel ...
Page 106: ...Protected Setup Pages 98 MVP 5200i Modero Viewpoint Widescreen Touch Panel ...
Page 174: ...Programming 166 MVP 5200i Modero Viewpoint Widescreen Touch Panel ...
Page 182: ...Battery Life and Replacement 174 MVP 5200i Modero Viewpoint Widescreen Touch Panel ...