Enova DGX DXLink™ Twisted Pair Boards
87
Instruction Manual – Enova DGX 8/16/32/64 Digital Media Switchers
* Dolby Digital and DTS support up to 48 kHz, 5.1 channels.
** For more details and helpful cabling information, reference the white paper titled “Cabling for Success with DXLink”
available at www.amx.com or contact your AMX representative.
*** “Common building” is defined as: Where the walls of the structure(s) are physically connected and the structure(s) share
a single ground reference.
AMX reserves the right to modify its products and their specifications without notice.
Enova DGX DXLink Twisted Pair Board
Specifications (continued)
Audio Format Support
Dolby TrueHD, Dolby Digital*, DTS-HD Master Audio, DTS*, 2 CH L-PCM, 6 CH L-PCM,
8 CH L-PCM
Audio Resolution
16 bit to 24 bit
Audio Sample Rate
32 kHz, 44.1 kHz, 48 kHz, 96 kHz, 192 kHz
Local Audio Support
Yes, insertion and/or extraction of 2 CH L-PCM selectable by channel
EDID Support
• EDID provided by Enova DGX Digital Media Switcher to the DXLink HDMI TX
• EDID provided by Enova DGX Digital Media Switcher to the digital (HDMI) input
on the DXLink Multi-Format TX
• EDID is user re-programmable
HDCP Support
Yes, full matrix HDCP support (includes any input to any or all outputs, except for
SC Optical inputs and outputs)
• Key Management System
• AMX HDCP InstaGate Pro
®
Technology
• Key support up to 16 destinations per output, independent of source device
CEC Support
None
ICSP, TCP/IP, USB, IR, and
Control Management
Control Distribution is managed by the Enova DGX Digital Media Switcher on-board
NetLinx Master and Ethernet Switch
DXLink Power
DXLink Transmitters and Receivers can have power supplied over twisted pair cable
when connected to a DXLink Input or Output Board on the Enova DGX Digital Media
Switcher
Input Board Propagation
Delay
5
s
Output Board Propagation
Delay
5
s
Connectors
4 RJ-45 ports
Twisted Pair Cable Type
Shielded Cat6, Cat6A, Cat7**
Twisted Pair Cable Length
Up to 328 ft. (100 m)**
Important Notice
DXLink twisted par cable runs for DXLink equipment shall only be run within a common
building.***
Twisted pair cable specs