Appendix F – Program Run Disable Mode
227
Instruction Manual – Enova DGX 8/16/32/64 Digital Media Switchers
6.
The PRD DIP switch is located at the back of the board behind the coin cell battery. Set the Position #1 DIP switch
to
ON
(places the integrated Master into PRD mode).
Note that the DIP switch is mounted with the ON position toward the front of the CPU board assembly.
7.
Slowly slide the CPU board back into the empty slot, being careful to align the edges in the board guides along the
insides (FIG. 135).
8.
Push the CPU board into the enclosure firmly enough to make a good electrical connection (avoid pushing on the
connectors). When fully inserted, the faceplate on the CPU board should sit flush with the back metal.
9.
Reattach the faceplate to the enclosure with the
screws that were removed in Step 3.
10.
Plug in
all four AC power cords
.
11.
Check the System Status LED on the CPU for indications of normal display (see the table below).
* A system is in IOS mode when an unexpected, temporary, critical error is trapped and logged and control is passed to the
host software (IOS) which prevents the normal appcode from running until the error is manually cleared. Please report all
such errors to technical support (see page 69).
12.
Re-attach the cables that were removed in Step 2.
13.
Execute a test switch to make sure the system is working correctly (see page 56).
14.
Use NetLinx Studio (v3.5.960 or later) to resolve the communication and/or control problems with the resident
NetLinx program.
15.
Download the corrected program.
16.
Follow Steps 1 through 13 again
for removing the CPU board and resetting the DIP switch.
This time, on Step 6, reset the Position #1 DIP switch to
OFF
(places integrated Master back into Normal mode).
17.
Try communication and/or control again.
Note:
For CPU troubleshooting information, see page 228.
FIG. 135
Set Position #1 DIP switch to ON
FIG. 136
Check System Status LED indicator
CPU LED Indicator
Normal Display
Cautionary Display
System Status
Constant green during power up, then
blinking green at 1/2 second on/off
intervals (this applies whether the
Master is in Normal mode or PRD
mode)
• Blinking red/green: an exception has been
logged in IOS (validation failure)
• Blinking red: dropped into IOS mode*
Board guides
Normal mode
PRD mode
Dip switch is located behind coin cell battery
System Status LED