![background image](http://html.mh-extra.com/html/amx/enova-dgx-8/enova-dgx-8_instruction-manual_2938068056.webp)
Installation and Setup
56
Instruction Manual – Enova DGX 8/16/32/64 Digital Media Switchers
Executing a Test Switch
For new system installations, we recommend executing a test switch to verify the system is working correctly before
attaching
all
inputs and outputs.
You must first disconnect the factory default switch of Input 1 routed to all outputs on
Virtual Matrix 1 (Level 1).
You can disconnect the factory default switch and execute a test switch from one (or more) of the following:
NetLinx Central Control Processor (Master)
XBar Controller (NetLinx WebConsole via TCP/IP)
Control Panel
BCS (Basic Control Structure) commands over an external controller
An external third-party controller (see product directions)
Before executing the test switch
:
Disconnect the factory default switch and make sure the first two source devices and the first two destination
devices are connected to the input and output connectors (for specific board connector information and
specifications, see the board chapter in this manual).
Any applicable DGX DXLink Modules / Wallplates or DGX Fiber Modules must also be installed
(see the product’s documentation).
Power must be applied to the enclosure and then to the source and destination devices.
When executing a test switch
, we suggest routing Input (source) 1 to Output (destination) 2 on the default virtual
matrix of VM 0, unless you know the system was ordered with custom VMs.
After the test switch has executed successfully:
If necessary, adjust the image with DGX Configuration Software, which is available at www.amx.com. This
software is used for configuring HDMI and DVI Boards (see page 172).
Disconnect the test switch before finishing the installation.
HDMI and DVI Boards – Additional Information
Before executing a test switch with HDMI and DVI Boards, we recommend reading the applicable board chapter which
covers HDCP issues and any EDID changes that may be needed (see the “Enova DGX HDMI Boards” chapter on
page 70 and the “Enova DGX DVI Boards” chapter on page 79).
NetLinx Central Control Processor (Master)
For disconnecting and executing switches using the NetLinx Central Control Processor, see the chapter on NetLinx
Programming on page 166.
XBar Controller (NetLinx WebConsole via TCP/IP)
For directions on disconnecting and executing switches using the XBar Controller, see page 158.
Control Panel
For directions on disconnecting and executing switches using the Control Panel on the front, see page 133.