Collect Touch
The Collect Touch Auto Scoping options determine how easily a control is placed in scope for Collect Touch. The
default is Mode Touch + On Entry.
The automatic scope settings are cumulative, as follows:
Off
No controls are automatically placed in scope,
i.e. scope has to be set manually as for normal
Automation Scope.
Mode Change
A control is automatically placed in Scope when
its automation mode changes to a Record mode
(e.g. Lock Record).
Mode
Touch
A control is also placed in scope when it is
touched.
Mode
Touch + On Entry
A control is also placed in scope if it is in an
automation Record mode when Collect Touch is
activated.
When the
Use Collect Touch Buffers
option is checked then using Collect Touch allows extra control setting
data to be stored in the Buffers. This is so that the Collect Touch Buffers can be used to rehearse and store
settings for overdubs, special audio effects and scene changes.
This option is checked by default.
Collect Touch Hard Write
causes controls that are put into Collect Touch Scope to automatically drop into full
record when a record mode is selected (i.e. as if the control was put into Lock Record and then touched - see
Automation Modes in the Automation chapter).
This option is checked by default.
Go To MTI Lock On Entering
forces Master Touch Isolate to be Locked when Collect Touch is initiated. This
prevents Master Touch Isolate from dropping out when the transport is stopped. This option is checked by
default.
Master Touch Isolate Respects Safety Nets
causes the new settings in the buffer(s) to be ignored outside the
Safety Nets. This means that a scene change can be previewed and rehearsed entirely in context, as it will be
recorded when Master Touch Record is engaged. This option is checked by default.
Clear Scope/Buffers on Exit
causes Collect Touch Scope and the Collect Touch Buffers to be cleared when the
COLLECT TOUCH key is turned off. This option is checked by default.
If this option is un-checked then Collect Touch Scope and Buffers will retain the settings from the last time Collect
Touch was used and Scope and the Buffers will have to be cleared manually.
Brightness Control Preferences
The Brightness Controls page is used to set the illumination levels for LEDs and displays on the console surface.
System Menu
Preferences
Issue 4
Page 18:8