Technical Information
58
Customer input
Port
Active
CTB1:
Description
Limits
Remote input
analog
1-2
0 – 10 Vdc (Zin = 21k
Ω
)
4-20mA (Zin = 250
Ω
)
see §3
Start
closed
3-4
provide isolated contact closure*
Stop
open
4-5
flow switch
closed
6-7
opened contact =
Ω
Fault
19Vdc@ 0.1A
E-stop
open
15-16
opened contact = stop
3Adc min
*) contacts rated for 24Vdc min, required wetting current 3mA
Equipment output
Description
Value
Units
Frequency
150 - 400
kHz
1-cap heat station
RF Current
1
3
5
7
10
12
tap
90
150
210
300
300
Apk max
2-cap heat station
RF Current
1
3
4
5
6
7
8
9
11
13
15
16
tap
90
120
150
180
210
240
270
330
390
400
400
Apk max
1kW model
2kW model
P
load
, deliverable
2
1
2
kW max
Eff’y, line-coil
>90
%
1.) refer to §3 for complete transformer settings information
2) using 2”, 4-turn coil with matched calorimeter
Customer output
Port
Active
CTB1:
Description
Limits
Ready
closed
8-9
isolated solid-state output, non-
polarized
24Vdc @ 1A
Heat On
closed
10-11
Fault
closed
12-13
24V dc
14-16
ground referenced
24V
±
2% @1A
4
4
.
.
3
3
E
E
n
n
v
v
i
i
r
r
o
o
n
n
m
m
e
e
n
n
t
t
a
a
l
l
Value
Range
Units
ambient temp
40 – 105 (4 – 41)
°
F (
°
C)
water temp
1
68 – 95 (20 – 35)
1kW model
2kW model
flow (minimum)
0.4 (1.5)
0.7 (2.6)
g/m (l/m)
pressure
2
40 – 80 (2.8 – 5.51)
lb/in
2
(bar)
pH
7
pH
conductivity
resistivity @25
°
C
less than 65000
greater than 2000
Ω•
cm
solids
less than 150
ppm
1.) Water temperature must not fall below the dew point in any case; condensation may result in nuisance
problems or damage to the equipment
2.) You must assure that the differential (inlet minus outlet) pressure falls within this range.