How Your E
ASY
H
EAT
Works
28
Multi-step profile
Case: the part is brought to temperature and held in three steps. From Control zone:
Do this...
Observe...
select
►
Adjust Profiles
then
press
; this selects Profile A
End
Start
Time
with A1 selected, press
►
Each step has 3 data points:
use
▲
/
▼
, set A1
Start
level
(ex: sets A1 Start = 50A)
press
►
use
▲
/
▼
, set A1
End
level
(ex: sets A1 End = 50A)
press
►
use
▲
/
▼
, set A1 step
Time
(ex: sets A1 Time = 10s)
press
►
Note A1 data points are displayed
use
▲
, select A2
set A2 Start = 50A
set A2 End = 200A
set A2 Time = 20s
use
▲
, select A3
set A3 Data points as shown
Clears all data for indicated step
select
►
System Options
,
, then
▲
select
Control from: ►File A
then select using
This step ‘activates’ File A;
FileA can be (de)activated any
time by selecting
Control from: ►Front
Panel
or
►Rear Panel
Home
press
START
Ready,
HeatOn, note three-
stage countdown until
Ω
Ready
only
Select Profile
►A B C D
0.0A 0.0A
Untimed►A1 Data
►50A
Start A1 Data
►50A
End A1 Data
►10s
Time A1 Data
50A 50A
10s ►A1 Data
50A 200A
20s ►A2 Data
200A 200A
10s ►A3 Data