Technical Information
53
801-9309.doc
if
*
persists, follow instructions
...until heating without
*
3
3
.
.
8
8
T
T
a
a
p
p
A
A
d
d
j
j
u
u
s
s
t
t
m
m
e
e
n
n
t
t
;
;
2
2
-
-
C
C
a
a
p
p
R
R
H
H
S
S
Under certain heating conditions, E
ASY
H
EAT
may ‘suggest’ changing your RF
transformer tap settings (§2, Advisories...). For example:
You can ignore this suggestion if:
•
your heating results are satisfactory
•
the
*
is displayed only when there is no
part in the coil
If you elect to follow this advice, follow these steps to change taps at the heat station:
Do this...
Observe...
STOP
unit is
Ready
turn off AC power switch at rear
AC power LED, panel are not lighted
at rear of heat station, use screwdriver to remove
wiring cover
use wrench, unscrew cord-grip flex; slide flex &
cover away from heat station
at terminal, note position of 2 wires
see guide, above; determine new positions
with screwdriver, loosen terminals securing wires;
move to new tap, per the notice
tighten wires in the new position
replace cover, secure with screws; replace cord grip
flex, tighten
turn on AC power switch
Navigate to Menu Selection > Heat Station
select
►
Modify Tap
select the new tap setting
returns to Home zone
during
HeatOn, an asterisk
*
is shown on
the display. To read the message,
press
for Status
There may be a message like this:
►250A 234.00s
220A *190kHz
HS65F AM72F
Increase Tap
Follow numbering on your heat station label; some models vary from the one shown.
6
7
8
9
11 13 15
16
5
Choose Menu
►Modify Tap