How Your E
ASY
H
EAT
Works
22
1button
:
HeatOn only while button is pressed
(or CTB1 signal closed), ceases when button is
released.(or CTB1 signal opens)
Control From
Control From
Control From
Control From
Front Panel
:
during
HeatOn, RF output
follows setpoint entered at front panel
Rear Panel
:
your analog signal controls output
File A...
:
use one of four profiles you specify
(§2.3)
RS485 4 Wire
:
if ‘Communication = RS485 4
Wire’, below, select this to adjust output with
serial command
Control From
►Front Panel