How Your E
ASY
H
EAT
Works
24
(Once this screen is displayed, press
; use
▲
/
▼
to select operating features):
Heat Station
Heat Station
Heat Station
Heat Station
This enables the power supply to operate after
you make changes to the heat station
configuration, or if you select from two different
heat stations. (Factory settings need never be
changed if you make no changes to the heat
station.)
To change, press
►
for changes to either
cap
acitor or to transformer
tap
settings
to select capacitance
Although factory-set, you must ‘inform’ the
E
ASY
H
EAT
of any
changes you make
to the RF
transformer taps or tank capacitor (see §3, tap
and capacitor changing instructions.
4
select the correct heat station model (
▲
,
▼
)
1000S
1000P
1000
800S
800P
400
300S
300P
150
Custom
(This information provided by us)
to select capacitance
▲▼
to adjust
to select next cap
to save
If you have changed the transformer tap setting
(§3), you must ‘inform’ the power supply:
select the correct tap setting (
▲
,
▼
)
Failure to change Tap or Cap
settings following a change may result in false displays
and loss of component protection. This does not change capacitance.
Choose Model
150
Choose Menu
►Modify Tap
Choose Menu
►Modify Cap
Select Tap
18
C1 Value
0.10uF
►
►
►
►
►
►
Menu Selection
►Heat Station
Whenever you are unsure about the correct tap selection for your application,
follow this rule:
start high, work down.
Beginning from the highest transformer
taps presents the least stress to the E
ASY
H
EAT
.