Technical Information
35
801-9309.doc
START/STOP
(CTB1:3-5)
Case: use
two
external signals, switches or isolated contacts to control RF heating:
START
signal is normally-open, active-closed,
STOP
is normally-closed, active-open.
2-Button...
Electrical
Touch-pad
Attach your signal:
►Setup
Start From ► RPan
Start Type ► 2-button
to Control
,
to Home
CTB1:3 =
START
N.O.
CTB1:4 =
COM
N.C.
CTB1:5 =
STOP
START
:
normally-open, active-closed at CTB1:3-4
STOP:
normally-closed; active-open at CTB1:4-5
Result:
START
signal (pulse) initiates heating; opening
STOP
signal halts heating.
Heating cannot commence whenever normally closed
STOP
signal is opened.
Case: You use
one
external signal, switch or isolated contact to control RF heating
1-Button...
Electrical
Touch-pad
Attach your signal:
►Setup
Start From ► RPan
Start Type ► 1-button
to Control
,
to Home
CTB1:3 =
START
N.O.
CTB1:4 =
COM
jumper
CTB1:5 =
STOP
Result: Closing
START
initiates heating, which continues while
START
is active;
opening
START
signal halts heating. Heating cannot occur whenever (jumpered)
STOP
signal is opened.
1-button Start is not recommended if you are using the timer (§2.1); the timer may re-
start if button is partially depressed or is held too long.
4
5