Technical Information
39
801-9309.doc
Pendant wiring diagram
Your pendant simply attaches to the rear of your E
ASY
H
EAT
at CTB1; we have made all
the wiring connections.
If you change this wiring or want to operate without the pendant, remember this:
•
a jumper is
required
from 4:com to 5:Stop
•
the jumpers shown from 15:System to 16:Source and from 6:FLS to 7:FLS are
required
To re-connect the pendant, follow the diagram above. All the jumpers shown are
required. If you are using an external flow switch, remove the jumper and attach the
switch from 6:FLS to 7:FLS.