![Amazone Precea 3000-A Original Operating Manual Download Page 176](http://html1.mh-extra.com/html/amazone/precea-3000-a/precea-3000-a_original-operating-manual_2919773176.webp)
4.
Release the lock
1
until the points
2
are
aligned.
1
2
CMS-I-00001910
5.
remove the singling disc
1
from the drive hub.
1
CMS-I-00001912
6.
To clean the opto-sensor, use tap water with
dishwashing detergent.
Loosen contamination with the supplied brush for
1 minute
7.
Rinse the opto-sensor with clear fresh water.
8.
Install the singling disc.
9.
Install the cover.
10.
To remove stubborn contamination, remove the
opto-sensor.
Remove the spring cotter pin
1
.
CMS-I-00003814
10 | Repairing the machine
Maintaining the machine
MG6659-EN-GB | F.1 | 25.10.2022 | © AMAZONE