For a conversion from 12 to 8 rows, longer hydraulic
hoses are needed between row 1 and 2 and between
row 11 and 12. This is the only way to shift the
remaining coulters to the desired row spacing after
the conversion.
16. Disconnect the connection
3
.
17. Remove the hydraulic hose
1
.
18. Install the long hydraulic hose from the sealing kit
between the coulters.
19.
To replace the second line
2
,
repeat steps 1 to 3.
1
3
2
CMS-I-00007202
20.
To set the coulter pressure to zero,
refer to the ISOBUS operating manual "Adjusting
the coulter pressure".
21. Switch on the fan at 2000 rpm.
NOTE
Ensure that the oil supply in the hydraulic unit is
sufficient.
22.
To vent the coulter pressure system on both
sides,
move the seeding units on both implement
sections up and down consecutively with a crane.
23.
When the hydraulic coulter pressure system has
been vented,
close the valve
3
.
24. Install the fastener
1
.
25. Install the bolt
2
.
1
3
2
CMS-I-00007310
6 | Preparing the machine
Preparing the implement for operation
MG6659-EN-GB | F.1 | 25.10.2022 | © AMAZONE