6.3.12 Creating tramlines
6.3.12.1 Configuring the tramline control
NOTE
The automatic tramline control requires an
electrically driven grain singling unit.
See "Configuring the tramline control" in the
ISOBUS software operating manual.
6.3.13 Calibrating the electrically driven fertiliser metering unit
6.3.13.1 Performing the calibration
REQUIREMENTS
The fertiliser hopper is at least
1
/
4
full with
fertiliser
1.
Switch off the fan.
2.
Release the lock
2
and swivel it downwards.
3.
To take the calibration buckets out of the
parking position on implements with hydraulic
fan drive,
pull out the interlocked calibration buckets
1
to
the side.
or
To take the calibration buckets out of
the parking position on implements with
mechanical fan drive,
pull out the calibration buckets individually to the
side on the left and right.
CMS-I-00001932
CMS-T-00001881-A.1
CMS-T-00001883-A.1
CMS-T-00003839-E.1
CMS-T-00001945-E.1
6 | Preparing the machine
Preparing the implement for operation
MG6659-EN-GB | F.1 | 25.10.2022 | © AMAZONE
95