18. Loosen the tension belt
2
from the top link
1
and lower link
3
and remove it.
2
1
3
CMS-I-00005312
19.
To set the coulter pressure to zero,
refer to the ISOBUS operating manual "Adjusting
the coulter pressure".
20. Switch on the fan at 2000 rpm.
NOTE
Ensure that the oil supply in the hydraulic unit is
sufficient.
21.
To vent the coulter pressure system on both
sides,
move the seeding units on both implement
sections up and down consecutively with a crane.
22.
When the hydraulic coulter pressure system has
been vented,
close the valve
3
.
23. Install the fastener
1
.
24. Install the bolt
2
.
1
3
2
CMS-I-00007310
6 | Preparing the machine
Preparing the implement for operation
MG6659-EN-GB | F.1 | 25.10.2022 | © AMAZONE
110