7.
Turn the drive unit
1
counterclockwise.
8.
Pull the drive unit out of the metering housing.
CMS-I-00002585
9.
Take the roller cage
1
along with the metering
roller out of the metering housing.
CMS-I-00002584
10. Clean the metering housing
11. Actuate the switchover flap
4
several times.
12. Actuate the bottom flap lever
1
several times.
13. Clean the outlets
2
and
3
.
CMS-I-00002577
10 | Repairing the machine
Maintaining the machine
MG6659-EN-GB | F.1 | 25.10.2022 | © AMAZONE
166