![Amazone Precea 3000-A Original Operating Manual Download Page 169](http://html1.mh-extra.com/html/amazone/precea-3000-a/precea-3000-a_original-operating-manual_2919773169.webp)
12. Release the lock
1
and swivel it downwards.
13.
To move the calibration buckets into calibration
position on an implement with hydraulic fan
drive,
pull out the interlocked calibration buckets
2
by
10 cm to the side.
or
To move the calibration buckets into calibration
position on an implement with mechanical fan
drive,
pull out the calibration buckets
2
individually by
10 cm to the side.
14. Turn the calibration bucket upwards and align the
opening with the guide marks
3
.
15. Insert the calibration bucket.
CMS-I-00001931
16.
To move the calibration flap lever to the
calibration position,
press and hold the lock button
1
and push it
down
2
.
17.
To move the bottom flap lever to the emptying
position,
press and hold the lock button
3
and push it
down
4
.
18. Clean the metering units thoroughly with a water
jet.
19. Clean the calibration buckets.
3
1
4
2
CMS-I-00001994
20. Push in the the calibration bucket
2
with the
opening facing down.
21. Swivel up the lock
1
and close it.
22.
To move the calibration flap lever into working
position,
press and hold the lock button and push it
upwards.
23.
To move the bottom flap lever into working
position,
press and hold the lock button and push it
upwards.
CMS-I-00001932
10 | Repairing the machine
Maintaining the machine
MG6659-EN-GB | F.1 | 25.10.2022 | © AMAZONE
163