CHAPTER 3: USING PROGRAMMING FUNCTIONS
IS-300CA INVERTER POWER SUPPLY
990-418
3-51
SQD
Closes the 1ST signal. When the 1ST signal is input, the force set in SQD is output to the electro
pneumatic proportional valve (ANALOG OUT), and SQD and CONTINUE blink.
The measured value input in the force input (ANALOG IN) is displayed at the monitor of SQD.
SQZ
The sequence proceeds from SQD to SQZ by press the ENTER key or input STEP MODE signal.
The force set in SQZ is output to the electro pneumatic proportional valve (ANALOG OUT), and
SQZ and CONTINUE blink.
The measured value input in the force input (ANALOG IN) is displayed at the monitor of SQZ.
WE1
The sequence proceeds from SQZ to WE1 by pressing the ENTER key or input the STEP MODE
signal. The force set in WE1 is output to the electro pneumatic proportional valve (ANALOG
OUT), and WE1 and CONTINUE blink.
The measured value input in the force input (ANALOG IN) is displayed at the monitor of WE1.
CO1/WE2
The sequence proceeds from WE1 to CO1/WE2 by pressing the ENTER key or input the STEP
MODE signal. The force set in CO1/WE2 is output to the electro pneumatic proportional valve
(ANALOG OUT), and CO1/WE2 and CONTINUE blink.
The measured value input in the force input (ANALOG IN) is displayed at the monitor of
CO1/WE2.
CO2/WE3
The sequence proceeds from CO1/WE2 to CO2/WE3 by pressing the ENTER key or input the
STEP MODE signal. The force set in CO2/WE3 is output to the electro pneumatic proportional
valve (ANALOG OUT), and CO2/WE3 and CONTINUE blink.
The measured value input in the force input (ANALOG IN) is displayed at the monitor of
CO2/WE3.