APPENDIX E: EtherNet/IP
TM
COMMUNICATIONS
IS-300CR INVERTER POWER SUPPLY
990-418
E-3
Section II. Setting up the Bus Controller IP Address
By default, the bus controller is pre-configured with an IP address of 192.168.100.1 (subnet
255.255.255.0). If the Allen Bradley
®
PLC also has a pre-configured IP address in this range (ex.
192.168.x.x), then the bus controller IP address does not need to be modified. The user can skip all of
the steps under this Section II and proceed on to Section III. If the Allen Bradley
®
PLC has a
preconfigured IP address of something other than 192.168.x.x, for instance in the 10.0.0.2 range with
(subnet 255.0.0.0), then follow the steps below to configure the bus controller IP address.
Setting up the IP Address of the Bus Controller
In order to connect to the bus controller webserver via a web browser at IP address 192.168.100.1, we
want to make sure that the current bus controller is not configured to some other unknown IP address.
Set both rotary switches to “F” position and cycle the power. The Bus Controller will automatically
reset the bus controller IP address back to the default IP address of 192.168.100.1.
The image on the left shows the switch position is at “0 0” position. To switch to “F
F” position, turn both knobs counter-clockwise by one tick from the “0” position to
the “F” position. The Bus Controller will now boot with default values:
FF
IP address:
Network mask:
Gateway:
192.168.100.1
255.255.255.0
192.169.100.254
Note:
The IP address stored in the flash memory is not changed.