APPENDIX C: SYSTEM TIMING
IS-300CA INVERTER POWER SUPPLY
C-14
990-418
stop is stopped to make the sequence move to the next cool
time(CO1).
c: Weld2 stop (WE2)
When the displacement weld stop (DISPLC) is set to the weld2 stop
on the DISPLACEMENT screen and the displacement sensor
arrives at the set displacement(g at the above figure), the weld2
stop is stopped to make the sequence move to the next cool
time(CO2).
d: Weld3 stop (WE3) When the displacement weld stop (DISPLC) is set to the weld3 stop
on the DISPLACEMENT screen and the displacement sensor
arrives at the set displacement(h at the above figure), the weld3
stop is stopped to make the sequence move to HOLD.
e: Delay time
When the delay time is set on the DISPLACEMENT screen, the
displacement (i at the above figure)after the delay time elapses is
measured.
(Notes)
The displacement of work detection is set as 0mm (reference point) at “j” (right before
SQD).
“k” at the end of work detection is set as 0mm (reference point) of weld stop and the
final displacement (0mm for work detection and 0mm for the final displacement monitor
are different.)
The displacement between “k” and “j” is the monitor displacement (WORK DETECT
MONITOR) for work detection.
The displacement between “j” and “i” is the monitored value of the final displacement
(DISPLACEMENT MONITOR).