APPENDIX D: COMMUNICATIONS
IS-300CA INVERTER POWER SUPPLY
D-24
990-418
IS-300CA Advanced / EtherNet/IP
TM
:
Screen 10 PRESSURE REGULATOR screen Common data
(Schedule No.: 000)
Example of data writing:
#01W000S10:1,0,0,200.0,0.40,00000,00000,00000,000.0,0.00,00000,00000,00000
[CR][LF]
Item
Contents
Character
String
Range
1
FORCE CONTROL MODE
n,
1 to 4
2
FORCE UNIT
n,
0:N 1:kgf 2:lbf
3
AIR PRESSURE UNIT
n,
0:Mpa 1:bar 2:psi
4
AIR CYLINDER DIAMETER of VALVE1 nnn.n,
000.0 to 500.0(mm)
5
MAX AIR PRESSURE of VALVE1
n.nn,
nn.n,
nnnn,
0.00 to 1.00(Mpa)
00.0 to 10.0(bar)
0000 to 0145(psi)
6
*1
MAXFORCE of VALVE1
nnnnn,
00000 to 99999(N)
00000 to 99999(kgf)
00000 to 99999(lbf)
7
*1
CONSTANT FORCE UP/DW of VALVE1 n,
0:UP 1:DOWN
8
CONSTANT FORCE of VALVE1
nnnnn,
00000 to 35000(N)
00000 to 03569(kgf)
00000 to 07868(lbf)
9
*1
CONSTANT LOW UP/DW of VALVE1
n,
0:UP 1:DOWN
10
CONSTANT LOW of VALVE1
nnnnn,
00000 to 35000(N)
00000 to 03569(kgf)
00000 to 07868(lbf)
11
*1
CONSTANT HIGH UP/DW of VALVE1
n,
0:UP 1:DOWN
12
CONSTANT HIGH of VALVE1
nnnnn,
00000 to 35000(N)
00000 to 03569(kgf)
00000 to 07868(lbf)
13
AIR CYLINDER DIAMETER of VALVE2 nnn.n,
000.0 to 500.0(mm)
14
MAX AIR PRESSURE of VALVE2
n,nn,
nn.n,
nnnn,
0.00 to 1.00(Mpa)
00.0 to 10.0(bar)
0000 to 0145(psi)
15
*1
MAX FORCE of VALVE2
nnnnn,
00000 to 99999(N)
00000 to 99999(kgf)
00000 to 99999(lbf)
16
*1
CONSTANT FORCE UP/DW of VALVE2 n,
0:UP 1:DOWN
17
CONSTANT FORCE of VALVE2
nnnnn,
00000 to 35000(N)
00000 to 03569(kgf)
00000 to 07868(lbf)
18
*1
CONSTANT LOW UP/DW of VALVE2
n,
0:UP 1:DOWN
19
CONSTANT LOW of VALVE2
nnnnn,
00000 to 35000(N)
00000 to 03569(kgf)
00000 to 07868(lbf)
20
*1
CONSTANT HIGH UP/DW of VALVE2
n,
0:UP 1:DOWN
21
CONSTANT HIGH of VALVE2
nnnnn
00000 to 35000(N)
00000 to 03569(kgf)
00000 to 07868(lbf)
*1 Items inhibited from setting (When setting data, omit these items.)
“,” is not transmitted, too.