APPENDIX D: COMMUNICATIONS
IS-300CA INVERTER POWER SUPPLY
D-6
990-418
b) Error Data
IS-300CA
Basic
Data strings:
!01000:E03,04,12,15,17[CR][LF]
A B C D E F G
A
Device No.
Fixed to 2 digits (01 to 31)
B
Schedule No.
Fixed to 3 digits (001 to 255)
C*
1
Error Code 1
Fixed to 3 digits (E01 to E31)
D*
1
Error Code 2
Fixed to 2 digits (01 to 31)
E*
1
Error Code 3
Fixed to 2 digits (01 to 31)
F*
1
Error Code 4
Fixed to 2 digits (01 to 31)
G*
1
Error Code 5
Fixed to 2 digits (01 to 31)
IS-300CA
Advanced
/
EtherNet/IP
TM
Data strings:
!01000:E03,04,12,15,17,19,22,26[CR][LF]
A B C D E F G H I J
A
Device No.
Fixed to 2 digits (01 to 31)
B
Schedule No.
Fixed to 3 digits (001 to 255)
C*
1
Error code 1
Fixed to 3 digits (E01 to E39)
D*
1
Error code 2
Fixed to 2 digits (01 to 39)
E*
1
Error code 3
Fixed to 2 digits (01 to 39)
F*
1
Error code 4
Fixed to 2 digits (01 to 39)
G*
1
Error code 5
Fixed to 2 digits (01 to 39)
H*
1
Error code 6
Fixed to 2 digits (01 to 39)
I*
1
Error code 7
Fixed to 2 digits (01 to 39)
J*
1
Error code 8
Fixed to 2 digits (01 to 39)
*1 The maximum number of Error Codes is five for IS-300CA
Basic
and eight for
Advanced
/
EtherNet/IP
TM
Models. In the case of only one error code, the error
codes D to G (
Basic
) and D to J (
Advanced
/
EtherNet/IP
TM
) are omitted.
For Error Codes, see
Chapter 5, Maintenance
.
*2 Error codes are transmitted when errors are detected.
For the monitored value error and counter error, however, the error is transmitted after
the monitored data is transmitted.