APPENDIX D: COMMUNICATIONS
IS-300CA INVERTER POWER SUPPLY
D-12
990-418
Item
Contents
Character
String
Range
11
TIME L of WE2 (lower limit)
nnn,
000 to 999 (ms mode)
000 to 050 (CYC mode)
12
CURRENT H of WE2 (upper limit)
n.nn,
0.00 to 9.99 (kA)
nn.n,
00.0 to 99.9 (kA)
13
CURRENT L of WE2 (lower limit)
n.nn,
0.00 to 9.99 (kA)
nn.n,
00.0 to 99.9 (kA)
14
VOLT H of WE2 (upper limit)
n.nn,
0.00 to 9.99 (V)
15
VOLT L of WE2 (lower limit)
n.nn,
0.00 to 9.99 (V)
16
POWER H of WE2 (upper limit)
nn.nn,
00.00 to 99.99 (kW)
nnn.n,
000.0 to 999.9 (kW)
17
POWER L of WE2 (lower limit)
nn.nn,
00.00 to 99.99 (kW)
nnn.n,
000.0 to 999.9 (kW)
18
PULSE H of WE2 (upper limit)
nnn.n,
010 to 100 (%)
19
TIME H of WE3 (upper limit)
nnn,
000 to 999 (ms mode)
000 to 050 (CYC mode)
20
TIME L of WE3 (lower limit)
nnn,
000 to 999 (ms mode)
000 to 050 (CYC mode)
21
CURRENT H of WE3 (upper limit)
n.nn,
0.00 to 9.99 (kA)
nn.n,
00.0 to 99.9 (kA)
22
CURRENT L of WE3 (lower limit)
n.nn,
0.00 to 9.99 (kA)
nn.n,
00.0 to 99.9 (kA)
23
VOLT H of WE3 (upper limit)
n.nn,
0.00 to 9.99 (V)
24
VOLT L of WE3 (lower limit)
n.nn,
0.00 to 9.99 (V)
25
POWER H of WE3 (upper limit)
nn.nn,
00.00 to 99.99 (kW)
nnn.n,
000.0 to 999.9 (kW)
26
POWER L of WE3 (lower limit)
nn.nn,
00.00 to 99.99 (kW)
nnn.n,
000.0 to 999.9 (kW)
27
PULSE H of WE3 (upper limit)
nnn.n
010.0 to 100.0 (%)
Summary of Contents for IS-300CA