
CHAPTER 3: USING PROGRAMMING FUNCTIONS
IS-300CA INVERTER POWER SUPPLY
990-418
3-31
j. NEXT
When the cursor () is displayed, pressing the
ENTER
key will change the display to the MODE
SELECT (2) screen.
k. STEPPER MODE
Select whether or not to perform step-up (step-down) operation, refer to the
STEPPER COUNT
Screen.
OFF
Step-up (step-down) will not be performed.
FIXED
Step-up (step-down) will be performed. (Stepwise)
LINER
Step-up (step-down) will be performed. (Linear)
NOTE:
RATIO
has an effect on
HEAT
only. Fixed for
UF/DL
. When the
HEAT
value multiplied
by
RATIO
falls below the
UF/DL
value, an error occurs.
The
COUNT
value works as each
STEP
value.
Example:
STEP1 0020 STEP2 0010
indicates
that
STEP1
is 20 times and
STEP2
is 10 times. The conditions for stepper count-up is the same
as the
TOTAL
counter.
l. SCHEDULE
Sets the selection method of schedule number.
EXT
Selects the schedule number by binary of the I/O terminal strip.
INT
Selects the schedule number by the SCHEDULE number of
the
Pendant
. (Note)
NOTE:
When setting SCHEDULE to INT, be sure to connect
the Pendant
and select the
SCHEDULE screen or the MONITOR screen.
(k)
(l)
(m)
(n)
(r)
(t)
(u)
(o)
(p)
(q)
(s)
(v)
Summary of Contents for IS-300CA
Page 1: ...990 418 REV D INVERTER POWER SUPPLY IS 300CA OPERATION MANUAL...
Page 26: ......
Page 30: ......
Page 92: ......
Page 104: ...APPENDIX A TECHNICAL SPECIFICATIONS IS 300CA INVERTER POWER SUPPLY A 4 990 418 Duty Cycles...