APPENDIX E: EtherNet/IP
TM
COMMUNICATIONS
IS-300CR INVERTER POWER SUPPLY
990-418
E-23
Section V. Digital/Analog I/O’s and Weld Data Controls
When online with the CPU in RSLogix 5000, the IS-300CR digital and analog inputs / outputs and
screen data can be accessed and controlled through the Controller Tags. The controllable input and
output tags of IS-300CR are defined under the “ioControl” group and the serial communication screen
data tags are defined under the screen1Data, screen2Data, …. screen9Data and screen10Data groups.
Controller Tag Definitions
IO Parameter Tags
ioControl.par.id
Device number tag of the IS-300CR unit to communicate with
(hardcoded to 1).
ioControl.par.scheduleNumber
Schedule number tag (1..255) to read / write from / to the
IS-300CR.
ioControl.par.screenNumber
Screen number tag (1..10) of the screen data to read /write from / to
the IS-300CR.
ioControl.par.dataToWriteToIS800
ASCII buffer contains the preview of screen data to be written to
the IS-300CR. This ASCII buffer gets populated only if the
ioControl.com.prepareWriteData tag is set to 1. This ASCII
buffer is intended for preview and debugging purposes.
ioControl.stat.readData
ASCII buffer contains the status and request screen data from the
IS-300CR.
Summary of Contents for IS-300CA