CHAPTER 3: USING PROGRAMMING FUNCTIONS
IS-300CA INVERTER POWER SUPPLY
990-418
3-7
When the upslope time is set in the pulsation welding. The upslope time is set, and the UF HEAT
setting of C and the HEAT setting of D are different.
A
B
A
B
C
D
When the downslope time is set in the pulsation welding. The downslope time is set, and the
HEAT
setting of
C
and the
DL HEAT
setting of
D
are different.
A
A
B
B
C
D
When the upslope time and the downslope times are set in the pulsation welding. The upslope
time and the downslope time are set, and the
UF HEAT
setting of
D
and the
DL HEAT
setting of
F
are different.
A: UP1 to 3 time
B: WELD1 to 3 time
C: UF1 to 3 HEAT
D: HEAT1 to 3
A: WELD1 to 3 time
B: DOWN1 to 3 time
C: HEAT1 to 3
D: DL1 to 3 HEAT