CHAPTER 3: USING PROGRAMMING FUNCTIONS
IS-300CA INVERTER POWER SUPPLY
990-418
3-33
・
STEPPER (step-up (-down) operation)
When the 1ST STAGE signal is input, VALVE 1 is output, and then SOL2 is output after SQD.
After SQD and SQZ, the sequence waits for the 2ND STAGE signal input. Next, when the 2ND
STAGE signal is input, the welding sequence after WELD1 starts.
U
U
D
D
WE1
WE2
U
D
HO
CO1
CO2
WE3
SQD SQZ TW
T
32 ,64 ,128 ,P )
(1 ,2 ,4 ,8 ,16
T
1ST STAGE
2ND STAGE
Va lve output (SOL1 )
Va lve output (SOL2 )
We ld ing sequence
Schedu le se lect ion
n. MONITOR DISP MODE
Sets the monitor display. This function is invalid when the Pendant is disconnected.
NORMAL
The monitor display is updated each time. It takes monitored
value computing time + display time (ms). Used when the part
cycle time is relatively slow.
* Communicated with the Pendant each time welding is complete.
LAST
The monitor display is not updated. When the MONITOR screen
is updated, the last measured value is displayed. Used when the
part cycle time is relatively fast.
Errors are also displayed only when updated (communicated with
the Pendant).
* Not communicated with the Pendant automatically.
o. RE-WELD
Select whether or not to supply welding current again
at the same location if the monitored current is lower
than the lower limit. The second welding current will
be 5% greater than the setting value.
Even when the welding current is supplied twice with RE-ELD, each count-up is done only once.
TOTAL
,
WELD/WORK
, and
STEPPER
Once
GOOD
None (below the lower limit setting for the second time). Once (The lower limit setting
or more for the second time). This cannot be used in combination with the off time (OFF).
When the off time is set,
RE-WELD
works as
OFF
even if
ON
. When
RE-WELD
is combined
with
STEPPER
, the welding current will be 5% greater than the value set for
STEPPER
.
ON
Welding current will be supplied
again.
OFF
Welding current will not be
supplied again.
(VALVE 1)
(VALVE 2)