APPENDIX D: COMMUNICATIONS
IS-300CA INVERTER POWER SUPPLY
990-418
D-11
Item
Contents
Character
String
Range
34
PULSATION of WE3 / WE3
repetition
nn,
01 to 19
35
INT3 / Interval 3
nnn,
000 to 999 (ms mode)
000 to 050 (CYC mode)
36
WELD TRANS FREQ /
Welding transformer frequency
nnnn,
0600 to 3000 (Hz)
Note) The last 2 digits are fixed to 00.
37
GAIN
nn,
1 to 9
38
VALVE
n,
1 to 2
39
TURN RATIO
nnn.n,
001.0 to 199.9
40
WELD ON/OF
n,
0: OFF 1: ON
41
VOLT COMP
nnn,
Fixed to 3 digits (000 to 100) (%)
42
PULSE LIM of WE1
nn.n,
Fixed to 4 digits (10.0 to 99.9) (%)
43
PULSE LIM of WE2
nn.n,
Fixed to 4 digits (10.0 to 99.9) (%)
44
PULSE LIM of WE3
nn.n
Fixed to 4 digits (10.0 to 99.9) (%)
The following is additional data for IS-300CA
Advanced
/
EtherNet/IP
TM
45
MAX CURRENT
nnn,
01 to 280 (kA)
46
TRANS#
n
1 to 5
*1 The setting of ms/CYC cannot be changed. You can change it via Screen 05 (SYSTEM data).
*3 Screen 02 (MONITOR SET data) Specific data in accordance with Schedule No. (Schedule No.:
001 to 255)
Example of data writing (Basic
,
Advanced
and
EtherNet/IP
TM
):
#01W001S02:999,000,99.99,00.00,9.99,0.00,99.99,00.00,100.0,999,000,99.99,00.00,9.99,0.00,99.
99,00.00,100.0,999,000,99.99,00.00,9.99,0.00,99.99,00.00,100.0
[CR][LF]
Item
Contents
Character
String
Range
1
TIME H of WE1 (upper limit)
nnn,
000 to 999 (ms mode)
000 to 050 (CYC mode)
2
TIME L of WE1 (lower limit)
nnn,
000 to 999 (ms mode)
000 to 050 (CYC mode)
3
CURRENT H of WE1 (upper limit)
n.nn,
0.00 to 9.99 (kA)
nn.n,
00.0 to 99.9 (kA)
4
CURRENT L of WE1 (lower limit)
n.nn,
0.00 to 9.99 (kA)
nn.n,
00.0 to 99.9 (kA)
5
VOLT H of WE1 (upper limit)
n.nn,
0.00 to 9.99 (V)
6
VOLT L of WE1 (lower limit)
n.nn,
0.00 to 9.99 (V)
7
POWER H of WE1 (upper limit)
nn.nn,
00.00 to 99.99 (kW)
nnn.n,
000.0 to 999.9 (kW)
8
POWER L of WE1 (lower limit)
nn.nn,
00.00 to 99.99 (kW)
nnn.n,
000.0 to 999.9 (kW)
9
PULSE H of WE1 (upper limit)
nnn.n,
010 to 100 (%)
10
TIME H of WE2 (upper limit)
nnn,
000 to 999 (ms mode)
000 to 050 (CYC mode)
Summary of Contents for IS-300CA
Page 1: ...990 418 REV D INVERTER POWER SUPPLY IS 300CA OPERATION MANUAL...
Page 26: ......
Page 30: ......
Page 92: ......
Page 104: ...APPENDIX A TECHNICAL SPECIFICATIONS IS 300CA INVERTER POWER SUPPLY A 4 990 418 Duty Cycles...