CHAPTER 3: USING PROGRAMMING FUNCTIONS
IS-300CA INVERTER POWER SUPPLY
3-10
990-418
f.
HEAT
Set the welding current for
WELD1
,
WELD2
, and
WELD3
, respectively. When
CTRL
is changed,
the content to be set also change. Also, the settable range of welding current changes depending
on the current range.
UF (UP SLOPE FIRST)
Sets the initial current value of upslope. The set value is the as
HEAT
.
DL (DOWN SLOPE LAST)
Sets the final current value of downslope. The set value is the as
HEAT
.
NOTE:
When
UP/DOWN
is set,
UF/DL
becomes effective. It becomes a target value in the
effective value control, so a difference occurs between the set value and the value of actual
welding.
DANGER
Even though E-07 (No-current error) is displayed, current
is flowing. Exercise caution in handling
.
g. NEXT
When the cursor is at
, moving the cursor down will change the display to
PULSATION
and
transformer screen.
PULSATION and transformer screen
(b)
(d)
(e)
(f)
(g)
(a)
(h)
(c)
(i)
(j)
(k)
(l)
(m)