![Amada CD-A Series Operation Manual Download Page 85](http://html.mh-extra.com/html/amada/cd-a-series/cd-a-series_operation-manual_2915801085.webp)
APPENDIX D: COMMUNICATIONS
CD-A DUAL PULSE RESISTANCE WELDING POWER SUPPLY
990-430
D-7
SCHEDULE “SS” Set
<ACK
OR
NAK>
1 Byte
SCHEDULE “SR” Read
SCHEDULE # ,
2 Bytes
SQZ # (Squeeze Time),
4 Bytes
WS #1 (Energy in Watt Seconds),
4 Bytes
WS #2 (Energy in Watt Seconds),
4 Bytes
HOLD # (Hold Time),
4 Bytes
PULSE1 (
weld length
),
1 Byte
PULSE2 (
weld length
),
1 Byte
POLARITY1 (
weld polarity
),
1 Byte
POLARITY2 (
weld polarity
),
1 Byte
UP # (Up Slope, 0=Off, 1=On)
1 Byte
23 Bytes Total
-----------------------------------------------------------------------
weld length
0=Very short, 1=Short, 2=Medium, 3=Long
weld polarity
0=Positive, 1=Negative, 2=Alternating
MONITOR
“MS” Set
<ACK
OR
NAK>
1 Byte
MONITOR
“MR” Read
SCHEDULE #,
2 Bytes
P1 Upper Limit,
4 Bytes
P1 Lower Limit,
4 Bytes
P1 Action (
action
)
1 Byte
P2 Upper Limit
4 Bytes
P2 Lower Limit
4 Bytes
19 Bytes Total
-------------------------------------------------------------------------
action
0 = NONE, 1 = INHIBIT P2