![Amada CD-A Series Operation Manual Download Page 35](http://html.mh-extra.com/html/amada/cd-a-series/cd-a-series_operation-manual_2915801035.webp)
CD-A DUAL PULSE RESISTANCE WELDING POWER SUPPLY
990-430
3-1
CHAPTER 3
Using Display Screens
Section I: RUN Screen
RUN Screen
The
BLUE
RUN
screen is displayed whenever the
Power Supply is in
RUN
mode.
Squeeze and hold times are displayed in the upper
left and right corners of the screen.
Programmed values for energy, pulse width, weld
polarity and upslope are displayed in the upper
middle of the screen.
Weld limits, if any, and the peak weld current
monitor results for the last weld completed are
displayed in the middle of the screen.
The number of the currently active weld schedule
is displayed at the lower right corner.
In the lower middle of the screen the
WELD COUNTER
and process monitor indicate how many welds have
been completed since the weld counter was reset and what percentage of those welds were within
programmed limits, indicated both numerically and graphically. The
GREEN
bar on the screen above
indicates 95% of welds are within limits, the
RED
portion of the bar shows 5% of welds are outside limits.
The CD-A125A allows programmed values for
Energy in tenths of watt seconds for energy
settings between 1.0 and 10.0 Ws. The energy
settings for the CD-A125A between 10 and 125
Ws can
only
be set in whole number increments.
The energy settings for the CD-A300A and CD-
A1000A can
only
be set in whole number
increments.
The CD-A125A
RUN
screen is the same as the
CD-A300A and CD-A1000A
RUN
screens
except
the Energy setting is shown with the tenths digit
as shown in the screen shown on the right.