![Amada CD-A Series Operation Manual Download Page 21](http://html.mh-extra.com/html/amada/cd-a-series/cd-a-series_operation-manual_2915801021.webp)
CHAPTER 1: DESCRIPTION
CD-A DUAL PULSE RESISTANCE WELDING POWER SUPPLY
990-430
1-7
LIMITS / COUNTERS
Press this button momentarily to display the
Limits / Counters
screen. Press and hold this button for 1
second to display the
Limits / Counters
editing screen. Welding is
not
allowed when these screens are
displayed. Additional instructions on using the
LIMITS / COUNTERS
screen are in
Chapter 3, Using
Display Screens.
Pulse 1 & Pulse 2
Press and hold either of these buttons for approximately 1 second to put the unit into “edit” mode which
allows modification of weld schedule settings.
Press and hold the
Pulse 1
button, waiting for the screen background to change from
BLUE
to
BLACK
.
Energy, pulse width, and Polarity for Pulse 1 may now be edited. To accept changes, press the
SAVE
button. To exit “editing” mode
without
accepting changes, press the front panel
RUN
button, then at the
SAVE
prompt, press the
CLEAR
button to discard.
To edit
Pulse 2
parameters, follow the same procedures described for Pulse 1.
SQZ / HOLD
Pressing this button during edit mode causes the editing highlight to move to the
SQUEEZE
field.
Pressing this button again moves the highlight to the
HOLD
field.
SAVE
Pressing this button saves changes made during editing.
CLEAR
Press this button to clear the
WELD COUNTER
,
COUNTER LIMIT
,
PULSE 1 & PULSE 2 UPPER & LOWER
LIMIT
fields. Pressing this button discards changes made during editing at the
SAVE
prompt: Press
SAVE
to save changes
CLEAR
to discard.
CHARGE MONITOR Light
When the green
CHARGE MONITOR
light is lit, capacitors are fully-charged and ready to weld. The light
will turn off for a short time during the weld discharge period and while the capacitor bank is recharging.
Once capacitor charging has been completed, the
CHARGE MONITOR
light will again illuminate. When
the
WELD/NO WELD
switch is in the
NO WELD
position, the
CHARGE MONITOR
light will
not
light because
the system is not ready to weld.
WELD / NO WELD Switch
With the
WELD
switch is in the
WELD
position, weld current is enabled and programmed weld sequences
execute normally.