![Amada CD-A Series Operation Manual Download Page 26](http://html.mh-extra.com/html/amada/cd-a-series/cd-a-series_operation-manual_2915801026.webp)
CHAPTER 2: INSTALLATION AND SETUP
CD-A DUAL PULSE RESISTANCE WELDING POWER SUPPLY
2-4
990-430
Weld Head Connections to Power Supply Terminals
(non-force fired Weld Head)
1.
Turn the AC power OFF.
2.
Connect one end of a weld cable to the negative (
-
) welding transformer terminal on the Power
Supply (or external transformer for a CD-A1000A).
3.
Connect one end of the second weld cable to the positive (
+
) welding transformer terminal on
the Power Supply (or external transformer for a CD-A1000A).
4.
Connect the other ends of the weld cables to the weld head.
5.
Install electrodes in the weld head electrode holders.
NOTE:
If you need additional information about the weld heads, please refer to the
manufacturer's user manuals.
CAUTIONS:
1. Install weld cable washers between the screw heads and cable
terminals, NOT between the cable terminals and the control terminals.
2. Dress weld cables together with cable ties to minimize induction loss.
WELD HEAD
Weld
Cable
Washer
WELD
TERMINALS
(x2)
WELD
CABLES