CHAPTER 4: OPERATING INSTRUCTIONS
CD-A DUAL PULSE RESISTANCE WELDING POWER SUPPLY
990-430
4-5
6.
Press the
SAVE
button to save any changes made. To exit the “editing” mode
without
accepting
changes, press the
RUN
button
on the front panel, which will activate the
SAVE
prompt, then press
CLEAR
to discard changes.
Set Weld Counter Limit or Reset the Weld Counter
The
WELD COUNTER
and
COUNTER LIMITS
apply to all weld schedules. There is not a separate counter
or separate limit for each schedule. This feature is useful for counting welds made on a set of electrodes
to determine when to change electrodes. This feature can also be used to count the number of welds during
a particular shift or work day. After the limit is reached, the Power Supply will “beep” each time a weld
is made. This signals the Operator to take action. To clear the counter or edit limit values:
1.
Press the
LIMITS/COUNTERS
button to select this screen. Press and hold the
LIMITS/COUNTERS
button for about one second. The screen will turn black to indicate edit mode.
2.
The
WELD COUNTER
field will be highlighted. Press the
CLEAR
button to reset this value to
000000
.
NOTE:
The or arrows do
not
change the Weld Counter value.
3.
To change the
COUNTER LIMIT
field, press the
LIMITS/COUNTERS
button again. The
COUNTER
LIMIT
field will be highlighted. Press the
CLEAR
button to set this to zero or use the or
arrows to change the value.
4.
Press the
SAVE
button to save changes. To exit “editing” mode
without
accepting changes, press
RUN
to activate the
SAVE PROMPT
; then press
CLEAR
on the front panel to discard changes.
Set MENU Entries
The
MENU
screen contains set-up and configuration values that apply to all schedules.
1.
Press the
MENU
button to select this screen. Press and hold the
MENU
button for about one
second. The screen will turn black to indicate edit mode. The
BUZZER
field will be highlighted.
2.
To adjust the buzzer volume, press the or arrows to go from 1 (quiet) to 4 (loud).
3.
To set the RS-232 baud rate, press the
MENU
button again. The
BAUD
rate field will be
highlighted. Press the or arrows to select the desired baud rate.
4.
To set the input switch debounce time, press the
MENU
button again. Press the or arrows to
select either
0
or
30 MSEC
debounce time.
5.
To set the starting schedule for a weld chain, press the
MENU
button again. Press the or
arrows to select the starting schedule.
6.
To set the ending schedule for a weld chain, press the
MENU
button again. Press the or
arrows to select the ending schedule.
7.
Press the
MENU
button again to select the
REMOTE
field.
8.
Press the or arrows to select
ON
or
OFF
. When this is set to
OFF
, the Power Supply will not
accept RS-232 commands from a remote source to change schedule or control settings. When