APPENDIX D: COMMUNICATIONS
CD-A DUAL PULSE RESISTANCE WELDING POWER SUPPLY
D-6
990-430
STATUS
”TS” Read
Status of unit or the last weld.
2 Bytes
0 = GOOD
1 = Capacitors did not discharge in 15 seconds
2 = Capacitor does not charge in time
3 = Firing switch does not close within 10 seconds of FS2 closing
4 = The capacitor calibration value is outside of limits
5 = Internal EEPROM memory error
6 = Internal EEPROM values corrupted. Default values loaded
7 = Power board fuse blown
8 = Communication error between control board and front panel
9 = Exiting Edit mode
10 = Emergency Stop (EMO) input is open
11 = Invalid Chaining start or end value
12 = Last Weld was out of Limits
SYSTEM
“YS” Set
<ACK
OR
NAK>
1 Byte
SYSTEM
“YR” Read
BAUD RATE
(rate)
1 Byte
DEBOUNCE (0=None, 1=30ms)
1 Byte
BUZZER (0=Off, 1, 2, 3, 4=loud)
1 Byte
FAST WELD (0=OFF, 1=ON)
1 Byte
WELD MODE:
(0=FS1FS2FSW, 1= FS1FS2, 2=FSW) 1 Byte
REMOTE (0=Off, 1= On)
1 Byte
CHAINING START (0=Off, 01-63)
2 Bytes
CHAINING END (0=Off, 01-63)
2 Bytes
REPEAT MODE (0=OFF, 1=ON)
1 Byte
REPEAT TIME
3 Bytes
14 Bytes Total
-------------------------------------------------------------------------
rate
0=9600, 1=19.2 k, 2=38.4 k Baud