![Amada CD-A Series Operation Manual Download Page 44](http://html.mh-extra.com/html/amada/cd-a-series/cd-a-series_operation-manual_2915801044.webp)
CHAPTER 3. USING DISPLAY SCREENS
CD-A DUAL PULSE RESISTANCE WELDING POWER SUPPLY
3-10
990-430
REPEAT TIME
You should specify the
REPEAT TIME
so that it is
sufficient to allow the weld head to open the
electrodes and to allow you to reposition the work
piece before the entire welding sequence repeats.
When
REPEAT MODE
is set to
OFF
, this function
is deactivated.
REPEAT MODE showing REPEAT TIME
Note: Weld Mode set to FS1+FS2 for the timing shown below.
RUN
STATE
SQZ
HOLD
REPEAT
TIME
SQZ
HOLD
REPEAT
TIME
RUN
STATE
WELD
WELD
UP
UP
DOWN
WELD HEAD POSITION