CD-A DUAL PULSE RESISTANCE WELDING POWER SUPPLY
990-430
D-1
#6 – No Connection
#7 – No Connection
#8 – No Connection
#9 – No Connection
APPENDIX D
Communications
Section I. Introduction
Overview
The Power Supply has the ability to communicate with a host computer or with automation control
system. The communications option uses RS-232 to connect one control to one host.
Remote Programming
The codes needed to perform remote programming are listed in
Section II, Communications Protocol
and Commands
. Using these codes, users can write customized software for controlling all functions of
the welding control and interfacing the unit to automation control systems.
RS-232 Serial Connector Information
RS-232 settings
Baud Rate
9600, 19.2k, and 38.4k Baud
Data bits
8
Stop bit
1
Parity
None
NOTES:
•
The host must be set to the same baud rate as the unit.
•
For a microprocessor-based conversion (such as the Edgeport USB converter from Inside
Outside Networks), the host computer should be running the Windows operating system.
#1 -- No Connection
#2 -- RS-232 Transmit
#3 – RS-232 Receive
#4 – No Connection
#5 – Signal Ground