![Amada CD-A Series Operation Manual Download Page 25](http://html.mh-extra.com/html/amada/cd-a-series/cd-a-series_operation-manual_2915801025.webp)
CHAPTER 2: INSTALLATION AND SETUP
CD-A DUAL PULSE RESISTANCE WELDING POWER SUPPLY
990-430
2-3
Section II: CD-A125A & CD-A300A
External Equipment Connections
All connections between the Power Supply and external equipment other than the weld cable are made
through the rear panel.
Rear Panel Components and Connectors CD-A125A and CD-A300A
NOTE:
Weld cable connections are made on the front panel of the CD-A125A and CD-A300A and
the external transformer for the CD-A1000A is hooked up in the back.
Emergency STOP Switch
Connect an agency compliant, normally closed,
EMERGENCY STOP SWITCH
across the two leads of the
emergency stop switch connector cable. When this switch is opened, the weld cycle will immediately
stop. See
Appendix B. Electrical and Data Connections
for circuit details.
NOTE:
For operation
without
an
EMERGENCY STOP SWITCH
, verify that the two conductors of the
emergency stop cable are shorted together as the system will not operate if this loop is electrically open.
Foot Switch Connector
24VAC Air Valve Drive
24VDC Weld Head
Connector
RS-232 Connector
I/O Option Switch
Valve Drive Option Switch
Foot Switch Option Switch
Emergency Stop Switch
Connector Cable
Firing Switch Connector
Cable
37-Pin I/O Connector
ON / OFF Switch
Circuit Breaker
AC Power Connector