CPU-XL VariSpark IOM 07-21
All rights reserved © ALTRONIC, LLC 2021
18
21.2 The first mode selection can enable or disable the pre-configured retard curve
controlled by the 4-20mA current loop input. The choices are ON or OFF, with
the active selection displayed in capital letters. A PC is required to configure the
4-20mA curve; reference the programming instructions, form CPU-XL VariSpark
PI. When the current loop is on, the current loop value is displayed (xx.x mA) with
the “A” capitalized. When the current loop is off, the value is displayed (xx.x ma)
with the lower case “a”.
AT
NOTE: DISPLAY
SHOWS CURRENT
LOOP ON.
TO
TO
FOR
TO
TURN
TURN
NEXT
EXIT
ON
OFF
OPTION
NEXT
ESC
21.3 The next mode selection can enable or disable the pre-configured retard curve
controlled internally by engine RPM. To configure the RPM retard curve, refer to
the Programming Instructions, Form CPU-XL VariSpark PI.
AT THE
NOTE: DISPLAY
NEXT
SHOWS RPM
OPTION
MAP OFF.
SCREEN
TO
TO
FOR
TO
TURN
TURN
NEXT
EXIT
ON
OFF
OPTION
NEXT
ESC
⬆
⬇
⬆
⬇