CPU-XL VariSpark IOM 07-21
All rights reserved © ALTRONIC, LLC 2021
10
19.0 UNDERSTANDING THE HOME SCREEN
19.1 A series of home screens are used to describe the current status of the ignition
system. The LCD display always reverts back to one of the home screens after
a keypad operation is completed or times out. The home screen is designed to
display the most critical operating parameters on one screen.
19.2 The
READY
message is displayed when the ignition is ready for the engine to
crank for starting.
19.3 Once the engine begins turning, the
SYNCING
message is displayed while the
ignition system verifies signals from the engine pickups.
After the ignition system has synchronized with the engine, the system displays
TRYING. This message means that the system has begun firing.
19.4 The
FIRING
message is displayed after one channel of each Output Module has
fired at least once. When this is displayed, the fire-confirm signal is also closed.
Additional data is provided on this screen to describe the selected mode of
operation for the ignition. The spark mode (#1-8) is described beneath the status.
19.5 The
STALLED
message is displayed when a loss of rotation is detected after the
ignition is firing and neither a
SHUTDOWN
or
FAULT
has occurred. This signifies
that the engine has stopped without any detected cause from the ignition system.