When too many, or too few gear-
tooth pulses are seen between
reset pulses.
The received number of pulses is
displayed.
When the engine speed exceeds
the overspeed setpoint.
Maximum observed speed is also
displayed.
When the configuration and firing
data stored in EEPROM memory is
corrupted. This indicates that the
EEPROM memory must be replaced.
When the programming stored in
the Ignition processor is corrupted.
This indicates that the Ignition
processor must be replaced.
When the voltage supplied to the
left Output Module (rails 1 and 2)
has gone critically too high or too
low. This indicates either a bad
power supply, or a blown fuse
(located in the Junction/Diagnostic
Module).
When the voltage supplied to the
right Output Module (rails 3 and 4)
has gone critically too high or too
low. This indicates either a bad
power supply, or a blown fuse
(located in the Junction/Diagnostic
Module).