CPU-XL VariSpark IOM 07-21
All rights reserved © ALTRONIC, LLC 2021
45
28.4 If the difference between EAVG and CAVG reference numbers is greater than
the
LO FROM ENGINE
threshold, a diagnostic warning for that cylinder will
occur. This test will identify a cylinder whose voltage demand is too far below
the average engine voltage demand.
Default = 15
28.5 If the difference between CAVG and EAVG reference numbers is greater than
the
HI FROM ENGINE
threshold, a diagnostic warning for that cylinder will
occur. This test will identify a cylinder whose voltage demand is too far above
the average engine voltage demand.
Default = 15
28.6 If the COV reference number is greater than the
HI VARIATION COV
threshold,
a diagnostic warning for that cylinder will occur. This test will identify a cylinder
whose cycle-to-cycle voltage demand has become erratic.
Default = 30
Summary of Contents for VariSpark CPU-XL
Page 88: ...CPU XL VariSpark IOM 07 21 All rights reserved ALTRONIC LLC 2021 88 FIGURE 7 MAGNET ASSEMBLY...
Page 89: ...CPU XL VariSpark IOM 07 21 All rights reserved ALTRONIC LLC 2021 89 FIGURE 8 MAGNET ASSEMBLY...
Page 90: ...CPU XL VariSpark IOM 07 21 All rights reserved ALTRONIC LLC 2021 90 FIGURE 9 MAGNET ASSEMBLY...