CPU-XL VariSpark IOM 07-21
All rights reserved © ALTRONIC, LLC 2021
25
24.7 The next setup screen permits the operator to enter an ignition Test Mode. This
test mode can fire all outputs in rotation, or individual outputs at a slow rate. This
feature can be used to troubleshoot primary wiring and Output Module operation.
Test Mode will terminate if rotation of the engine is sensed. Diagnostic features do
not function while in Test Mode.
AT
PRESS
FOR
PRESS
PRESS
TO
TEST
MODE
FOR
NEXT
EXIT
OPTION
ENTER
NEXT
ESC
THEN
BEFORE
STARTING
TEST MODE
PRESS TO
PRESS TO
VERIFY
EXIT
PURGED
ENTER
NEXT
Then the Test Mode screen indicates that the ignition is firing and permits the
operator to select the output to be fired.
AT
PRESS TO
PRESS TO
PRESS TO
SELECT
SELECT
EXIT
PREVIOUS
THE NEXT
OUTPUT
OUTPUT
ESC
Test Mode selection is described below:
ALL - Rotate through all cylinders in the fire order
1-N -Fire individual cylinder; the cylinder’s label and connection will be
displayed. If the firing is detected at a different location or not detected at all,
an asterisk ‘*’ will be displayed next to the location.
NOTE: The Test Mode is enabled by
the user during initial setup of Logic/
Display Module from PC terminal
program. See form CPU-XL VariSpark
PI for details.
WARNING: The operator MUST fully
purge the engine of combustible mix-
tures prior to selecting the test mode
operation. Pressing the enter key again
is a confirmation of this action.
⬆
⬇
Summary of Contents for VariSpark CPU-XL
Page 88: ...CPU XL VariSpark IOM 07 21 All rights reserved ALTRONIC LLC 2021 88 FIGURE 7 MAGNET ASSEMBLY...
Page 89: ...CPU XL VariSpark IOM 07 21 All rights reserved ALTRONIC LLC 2021 89 FIGURE 8 MAGNET ASSEMBLY...
Page 90: ...CPU XL VariSpark IOM 07 21 All rights reserved ALTRONIC LLC 2021 90 FIGURE 9 MAGNET ASSEMBLY...