24.12 The
FIRE ORDER
menu allows the user to configure the CPU-XL to correctly
associate physical cylinders with the correct connected EZRail location. The
system uses a simple identification of rails (1-4) and coils (A-E). Rails 1 and 2 are
the upper and lower rail of the first (left) Output Module. Rails 3 and 4 correspond
to the lower and upper rails of the second (right) Output Module. This is required
in order to be able to correlate cylinder diagnostic information with the actual
physical cylinder and has no bearing on the actual fired cylinder.
AT
PRESS TO
PRESS TO
PRESS TO
ACCESS
GO TO THE
EXIT
THE MENU
NEXT MENU
ESC
AT
⬆
⬇
ENTER
NEXT
ENTER
NEXT
⬆
⬇
ENTER
NEXT
RESET
DIAG
ESC
PRESS TO
MOVE BETWEEN
CYLINDER,
RAIL, COIL
AND SLAVE
PRESS
TO
EXIT
PRESS TO
MODIFY
THE
VALUE
PRESS TO LOAD
A HARD-CODED
DEFAULT THAT
ENABLES ALL
THE CYLINDERS
AND COILS
PRESS TO ATTEMPT
TO VERIFY THE
PROGRAMMED
ORDER (MUST BE
DONE ON A RUNNING
ENGINE - SEE BELOW)
PRESS
TO GO
TO THE
NEXT
MENU
Summary of Contents for VariSpark CPU-XL
Page 88: ...CPU XL VariSpark IOM 07 21 All rights reserved ALTRONIC LLC 2021 88 FIGURE 7 MAGNET ASSEMBLY...
Page 89: ...CPU XL VariSpark IOM 07 21 All rights reserved ALTRONIC LLC 2021 89 FIGURE 8 MAGNET ASSEMBLY...
Page 90: ...CPU XL VariSpark IOM 07 21 All rights reserved ALTRONIC LLC 2021 90 FIGURE 9 MAGNET ASSEMBLY...