This screen shows the current running RPM as reported by the ignition system and
the minimum and maximum RPM as observed over the last 5 minutes of operation.
In this case, a minimum of 292 and maximum of 307 RPM were observed. It also
shows the level of variation (error) that may exist between the ignition RPM and
the actual RPM; in this case 1RPM. Lastly, the screen shows the timeframe being
observed (1-5 minutes of operation – in this case, 3 minutes).
Pressing
ENTER
will toggle the arrows in the upper left-hand corner of the
graph and change the role of the up and down arrow keys.
n
When the arrows are (left/right), using the
↓
↑
(up/down) arrow keys will
shift the time period being displayed (to view data earlier/later than what is
currently being graphed).
n
When the arrows are
~
(left and right) using the
↓
↑ (
up/down) arrow keys
will adjust the scale of the graph in the X direction (Time). This will cause
the graph to change the length of time displayed (from 1-5 minutes).
n
When the arrows are
é
(up/down), using the
↓
↑ (
up/down) arrow keys will
adjust the center of the graph in the Y direction (RPM). This change is
stored in EEPROM memory.
n
When the arrows are
üÇ
(up and down), using the
↓
↑ (
up/down) arrow keys
will adjust the scale of the graph in the Y direction (RPM). This change is
stored in EEPROM memory.
⬆
⬇