MN-36580 (Rev. 2) 01/16 • Quickchillers • 6
s I t e I n s t a l l a t I o n
I n s t a l l a t I o n
qc2-100 bottom View
Water DraInage
A 1" NPS drain is located under the QC2-100. Connect
the drain pipe using Teflon tape to discharge through
an indirect waste pipe into an open-site drain by
means of a 2" (51mm) air gap. Connection must be
within 10' (3m) of the unit.
NotICE
:
In the U.S.A., this equipment is to
be installed to comply with the Basic
Plumbing Code of the Building Officials
and Co de Administrators International,
Inc. [BOCA], and the Food Service
Sanitation Manual of the Food & Drug
Administration [FDA].
15-1/2" (394mm)
Hinged Left
35-1/2" (902mm)
Hinged Right
17-5/8" (447mm)
Front
DraInage
QC2-3
QC2-20
QC2-40
Evaporator pan: no InstallatIon rEqUIrEd
QC2-100
onE (1) Floor draIn:
1/2" (12,7mm) dIamEtEr
Drain
It is recommended that legs be attached to
the unit before installing drain assembly.
Leg Installation - QC2-100
Water Drainage
leg InstallatIon - qc2-100
1. Avoiding trolley guides and drain, carefully lift unit
off of floor with forklift just high enough to fit leg
assembly
(1)
and tools.
2. Pound feet
(2)
into frame
(1)
.
3. Align frame with holes on the bottom of the unit.
Insert screws
(4)
through nut inserts
(3)
and attach
to frame using a 3/8" socket.
4. Adjust feet accordingly to level the unit.
1
1
2
2
4
3
19mm
19mm
51mm
51mm