MN-36580 (Rev. 2) 01/16 • Quickchillers • 16
t I t l e
o p e r a t I o n
chIll processIng cycles
The Alto-Shaam Quickchiller uses high velocity
cold air circulation to remove heat from prepared
foods for the purpose of rapidly reducing
temperatures through the danger zone and
providing maximum storage life. Cold air is evenly
directed across each pan from the control side of
every Quickchiller model to assure rapid cooling.
The high velocity cold air produced by the
Quickchiller removes insulating layers of warm
moist air that surrounds hot products. The rapid
removal of these insulating layers of heat reduces
food temperatures significantly faster than any
other method of temperature reduction and
provides enhanced food safety.
Because the basic performance of the Quickchiller
relies on high velocity air movement around each
container of food, it is important to load the food
by placing pans directly into the pan slides. Always
use the pan slides to support the edges of 12" x 20"
steam table pans (GN 1/1). Use a wire shelf for pan
support when using 18" x 26" sheet pans; 12" x 10"
steam table pans (GN 1/2); loaf pans; entree plates;
and other small containers.
quIckchIller operatIon MoDes
➤
processIng WIth the use of probes
Probe usage provides chill or frozen food
processing activation and termination through
use of a food probe or probes inserted into the
center of the food. The cycle is automatically
terminated when the center of the food reaches
the probe sensing temperature set by the
operator. In units with multiple probes, all
probes much reach the sensing temperature set
by the operator to trigger automatic termination
of the cycle.
➤
processIng by tIMe
The time mode provides processing activation
and termination based on a timed cycle selected
by the operator. Upon expiration of the timed
cycle, the cabinet automatically reverts to the
designated holding cycle temperature.
➤
holDIng
Following processing completion, a holding
cycle maintains the temperature to safely
hold foods after processing. The holding cycle
will also maintain a holding compartment
temperature between processing cycles.
InItIal quIckchIller operatIon
prechIllIng the cabInet
The Quickchiller should be prechilled prior
to placing hot foods into the cabinet. In models
equipped with an optional roll-in cart (trolley),
always maintain an empty food cart inside the
chiller when prechilling to eliminate air loss
through the bottom of the chiller cabinet door. An
optional Prechill Sealing Strip (Item #
SA-35079
)
may also be used for this purpose.
Optional Prechill Sealing Strip
SA-35079
Optional Narrow Prechill Sealing Strip -
Contact Factory
c a u t I o n
TO MAINTAIN SANITATION
CONTROL, ALL FOODS FOR
QUICK-CHILL OR QUICK-FREEZE
PROCESSING MUST BE AT A
TEMPERATURE ABOVE 140°F (60°C)
AND MUST BE TIGHTLY COVERED.
Chill Processing Cycles
Operation Modes
Prechilling