MN-36580 (Rev. 2) 01/16 • Quickchillers • 4
InstallatIon requIreMents
Unit should not be tipped on its side.
If tipped, unit must stand in the
upright position for a mInImUm of 12
hours before operating. tipping will
cause damage to the unit and void the
warranty if not allowed to "rest"
.
— Appliance must be installed level.
— The appliance must not be installed in any area
where it may be affected by steam, grease, dripping
water, extreme temperatures, or any other severely
adverse conditions.
In order to maintain standards established by the
National Sanitation Foundation, all counter mounted
equipment must use legs that allow for a 4" (102mm)
clearance between the cabinet and the counter.
W a r n I n g
Appliance and accessories may be
heavy. To prevent serious injury,
ALWAYS use a sufficient number
of trained and experienced workers
when moving or leveling appliance
and handling accessories.
5-Year Limited
Warranty on
self-contained
compressor
Effective from date of
shipment. (
excludes
labor
)
Position the
Quickchiller to allow
sufficient air ventilation
through the condensing
unit(s).
Avoid installing the
chiller immediately
adjacent to fryers,
charbroilers, or any
other equipment
producing grease laden
air; heat producing
equipment such as ovens
and ranges; and steam
discharging equipment such as steamer ovens
and kettles. Do not locate the Quickchiller in
direct sunlight.
Allow sufficient front clearance for serviceability
and for easy maneuvering of food trolleys in and
out of the cabinet.
InstallatIon
Prior to moving the Quickchiller to the installation
site, check the dimensions of doors, passageways, and
ceiling heights in the areas through which the cabinet
must be moved. Also check the turning radius if the
cabinet must be moved around an existing structure.
The use of a fork lift or pallet lift truck is required for
moving and leveling most Quickchiller models.
NotICE
: In certain instances, it may be necessary
to remove doors and door hardware to
negotiate tight spaces.
®
W a r n I n g
Improper installation, alteration,
adjustment, service, cleaning, or
maintenance could result in property
damage, severe injury, or death.
READ and UNDERSTAND the
installation, operating and
maintenance instructions thoroughly
before installing, servicing, or
operating this equipment.
I n s t a l l a t I o n
s I t e I n s t a l l a t I o n
clearance requIreMents
top
0" (0mm)
each
side
1" (25mm)
18" (457mm)
minimum
from
heat
producing
equipment
Installation
Site Installation
Clearance Requirements
Installation Requirements